Spot Welding Robots from Nachi Robotic Systems Inc
Nachi's ST Fast Series (ST133F, ST166F, and ST210F) and ST Slim Series (ST70L and ST100) hav……...

Alpha, beta, gamma and X-ray radiation can be detected using silicon PIN photodiodes either indirectly via the measurement of the luminescence radiation of a scintillation crystal or directly via the absorption in the crystal lattice. The Series X from First Sensor has optimized silicon PIN photodiodes, which form broad, fully depleted space-charge regions even at low reverse voltages so as to ensure maximum absorption of radiation. For high-energy radiation, First Sensor offers detectors with a CsI:TI scintillation crystal.
Special Features
Very low capacitance levels
Very low dark current signals
Minimal series resistance at full depletion
Features
Very compact design
Two-stage charge amplifier, filter amplifier and comparator
High sensitivity for Cs137
100 mm² PIN detector with 8 mm CsI:Tl scintillator
Description
The high energy gamma radiation detector module with 100 mm² photodiode and 8 mm CsI:Tl scintillator. Pulse output for easy integration in gamma radiation detection instruments.
Application
Personal dosimeter
Medical equipment
Ionizing radiation detector
Technical Specifications and PDF Datasheet
| Order # | Chip | Package | Active Area Size (mm) / Area (mm²) | Dark current (nA) | Capacitance (pF) | Gamma-energy (KeV) | Scintillator CsI (TI) | window |
|---|---|---|---|---|---|---|---|---|
| 501559 | X7-F | CSP | 2.8 x 2.8 / 6.2 | 0.015 | 12 | - | no | - |
| 501400 | X100-7 | CerPin | 10 x 10 / 100 | 3 | 80 | >5 | no | black epoxy |
| 50147702 | X100-7 | CerPin | 10 x 10 / 100 | 5 | 80 | 5..>1000 | 4 mm | white coating |
| 50147701 | X100-7 | CerPin | 10 x 10 / 100 | 5 | 80 | 5..>1000 | 8 mm | white coating |
Nachi's ST Fast Series (ST133F, ST166F, and ST210F) and ST Slim Series (ST70L and ST100) hav……...
Tobii Pro is the business unit within Tobii Group that helps business and science professionals g……...
Award-Winning Products for Life ScienceOur multi-award winning products include the Reviewers&rsq……...
The Bruker name has become synonymous with the excellence, innovation and quality that characteri……...
Enviva is a leading global energy company specializing in sustainable wood bioenergy. We are the ……...
The Lince6M5 is a single chip, fully digital, high speed CMOS active pixel sensor. It is a very v……...
The panel measuring table supplies fast information on the etching distribution after differential etching processes or on the thickness of copper plating. The measurements are carried out fully au……
Oakton Temp-300 Dual-Input Thermocouple Datalogging Thermometer logs up to 2000 sets of readings in real time with date and time stamp. USB output lets you transfer data to your computer. Automatic……
Monnit Corporation was established to capitalize on the emerging trend of connecting to, monitoring and controlling machines and other “things” in our environment. Their backgrounds in ……