Military-Grade Strain Gage Amplifier: Model 5804

上海仪舶实验室自动化 25-03-24 10:10:04

Military-Grade Strain Gage Amplifier: Model 5804

The Columbia Model 5804 Military-Grade Strain Gage Amplifier is used to amplify signals from Columbia’s Full-Bridge Strain Sensors in the DT and DTD Series. The system provides both strain and temperature outputs.

In the case of input offset equivalent strains in that range, the strain output features a microprocessor-driven auto zeroing circuit effective in adjusting for input offsets of up to ±3000 µє equivalent and will instantly drive the output to 0.00 VDC.

This function enables the operator to compensate for any strain offsets caused by gage installation, material fatigueor deformation.

Auto zeroing can be done automatically when the power is turned on, or manually using the auto-zero function pin on the power connection.

A 1000 Ω platinum RTD offers a linearized temperature output of 40 mV / Deg C from -40 °C (0.00 V) to +85 °C (5.00 V). Over its rated operational range, the temperature output will stay within ±3° or ±120 mV of the straight line going through these two locations.

Strain andTemperature Outputs

Auto Zeroing Capability

Wide Input Power Range

Connects to any Columbia Full Bridge Strain Sensor

Specifications

Operational

Table 1. Source: Columbia Research Laboratories, Inc.

Operational 5804
Power Required +15 to +35 VDC (+28 VDC Nom.)
DC Current Drain 25 mA Max.
Strain Signal Output1 ±5.000 VDC 0.00 VDC= 0 Micro StrainsStandard:Output corresponding to ±5000 μϵOptional:Output corresponding to Specified Range
Temperature Output 0.0 VDC @ -40 °C and 5.00 VDC @ +85 °C ±3° or ±120 mV of straight line passing thru
Temperature Scale Factor 40 Mv/°C Nominal
Output Protection Over-Voltage and Over-Current Protection on both Strain and Temperature Outputs
Measurement Accuracy (Strain) ±5%
Electronic Filtering2 2-Pole Butterworth Filter with response set to -3 dB @2000 Hz
Fault Detection The amplifier will provide fault detection on all four strain sensor lead wires with a positive indication ofany combonation of broken or unconnected strainsensor lead wires. Faults will be indicated by anout-of-range output from the amplifier at the end ofthe auto-zeroing period. Open fault detection of thetemperature probe is intrinsic.
Operating Temperature -40 to +85 °C

Physical

Table 2. Source: Columbia Research Laboratories, Inc.

Physical 5804
Size 1.800 ± 0.010" Square x 0.602 ± 0.015" High
Mounting (3) #6 Clearance Holes
Weight 55 gm Nominal
Case Seal Epoxy
Grounding Case Isolated from Signal / Power Ground
Power Interface Cannon MSN-9PSB Connector
Sensor Interface Cannon MDM-9SSP Connector

1 Specify optional Strain Output Range as model number suffix (e.g. Model 5804 - Range ± XXXX μϵ)2 Optional cutoff Frequencies Available

Military-Grade Strain Gage Amplifier: Model 5804

Image Credit: Columbia Research Laboratories, Inc.

Sensor PinFunctions

Table 3. Source: Columbia Research Laboratories, Inc.

. .
1 Bridge Drive (+)
2 Bridge Output (+)
3 Bridge Output (-)
4 Bridge Drive (-)
5 Shield/Case Ground
8
9

Amplifier PinFunctions

Table 4. Source: Columbia Research Laboratories, Inc.

. .
1 +DC Power Input
9 DC Power Ground
7 Strain Output
3 Temperature Output
5 Signal Ground
4 Auto Zero Select
8 Shield/Case Ground
[Military-Grade Strain Gage Amplifier: Model 5804]相关推荐
Flow Meter - NivuFlow 600

Flow Meter - NivuFlow 600

The NivuFlow 600 is designed for flow measurement of full pipes. It allows for highly accurate fl……...

ATC Drivetrain

ATC Drivetrain

ATC Drivetrain is a world leader in remanufacturing solutions for light-, medium-, and heavy-dut……...

OMEGA Engineering Ltd

OMEGA Engineering Ltd

Since its inception in 1962, OMEGA has grown from manufacturing a single product line of thermoco……...

今日仪器
  1. Panasonic Industry Europe GmbH

    Panasonic Industry Europe GmbH

    Founded in 1981 as SDS-Relais, and incorporated into the Matsushita Electric Works global group in 1989 (now Panasonic Electric Works), the company was renamed Panasonic Electric Works UK Limited (……

    进口品牌 2025-08-18

  2. Mitsubishi Electric & Electronics USA, Inc., Solar/Photovoltaic Division

    Mitsubishi Electric & Electronics USA, Inc., Solar/Photovoltaic Division

    With over 80 years of experience in providing reliable, high-quality products to both corporate clients and general consumers all over the world, Mitsubishi Electric Corporation is a recognized wor……

    进口品牌 2025-08-18

  3. Cubic Gas Sensing Solutions for Pulmonary Function Testing

    Cubic Gas Sensing Solutions for Pulmonary Function Testing

    Pulmonary function tests serve as a valuable tool for assessing and monitoring the functionality of patients' lungs. Among these tests, spirometry is the most commonly utilized method to measu……

    进口仪器 2025-08-18

返回顶部小火箭