Military-Grade Strain Gage Amplifier: Model 5804

上海仪舶实验室自动化 25-03-24 10:10:04

Military-Grade Strain Gage Amplifier: Model 5804

The Columbia Model 5804 Military-Grade Strain Gage Amplifier is used to amplify signals from Columbia’s Full-Bridge Strain Sensors in the DT and DTD Series. The system provides both strain and temperature outputs.

In the case of input offset equivalent strains in that range, the strain output features a microprocessor-driven auto zeroing circuit effective in adjusting for input offsets of up to ±3000 µє equivalent and will instantly drive the output to 0.00 VDC.

This function enables the operator to compensate for any strain offsets caused by gage installation, material fatigueor deformation.

Auto zeroing can be done automatically when the power is turned on, or manually using the auto-zero function pin on the power connection.

A 1000 Ω platinum RTD offers a linearized temperature output of 40 mV / Deg C from -40 °C (0.00 V) to +85 °C (5.00 V). Over its rated operational range, the temperature output will stay within ±3° or ±120 mV of the straight line going through these two locations.

Strain andTemperature Outputs

Auto Zeroing Capability

Wide Input Power Range

Connects to any Columbia Full Bridge Strain Sensor

Specifications

Operational

Table 1. Source: Columbia Research Laboratories, Inc.

Operational 5804
Power Required +15 to +35 VDC (+28 VDC Nom.)
DC Current Drain 25 mA Max.
Strain Signal Output1 ±5.000 VDC 0.00 VDC= 0 Micro StrainsStandard:Output corresponding to ±5000 μϵOptional:Output corresponding to Specified Range
Temperature Output 0.0 VDC @ -40 °C and 5.00 VDC @ +85 °C ±3° or ±120 mV of straight line passing thru
Temperature Scale Factor 40 Mv/°C Nominal
Output Protection Over-Voltage and Over-Current Protection on both Strain and Temperature Outputs
Measurement Accuracy (Strain) ±5%
Electronic Filtering2 2-Pole Butterworth Filter with response set to -3 dB @2000 Hz
Fault Detection The amplifier will provide fault detection on all four strain sensor lead wires with a positive indication ofany combonation of broken or unconnected strainsensor lead wires. Faults will be indicated by anout-of-range output from the amplifier at the end ofthe auto-zeroing period. Open fault detection of thetemperature probe is intrinsic.
Operating Temperature -40 to +85 °C

Physical

Table 2. Source: Columbia Research Laboratories, Inc.

Physical 5804
Size 1.800 ± 0.010" Square x 0.602 ± 0.015" High
Mounting (3) #6 Clearance Holes
Weight 55 gm Nominal
Case Seal Epoxy
Grounding Case Isolated from Signal / Power Ground
Power Interface Cannon MSN-9PSB Connector
Sensor Interface Cannon MDM-9SSP Connector

1 Specify optional Strain Output Range as model number suffix (e.g. Model 5804 - Range ± XXXX μϵ)2 Optional cutoff Frequencies Available

Military-Grade Strain Gage Amplifier: Model 5804

Image Credit: Columbia Research Laboratories, Inc.

Sensor PinFunctions

Table 3. Source: Columbia Research Laboratories, Inc.

. .
1 Bridge Drive (+)
2 Bridge Output (+)
3 Bridge Output (-)
4 Bridge Drive (-)
5 Shield/Case Ground
8
9

Amplifier PinFunctions

Table 4. Source: Columbia Research Laboratories, Inc.

. .
1 +DC Power Input
9 DC Power Ground
7 Strain Output
3 Temperature Output
5 Signal Ground
4 Auto Zero Select
8 Shield/Case Ground
[Military-Grade Strain Gage Amplifier: Model 5804]相关推荐
Wuntronic GmbH

Wuntronic GmbH

Wuntronic GmbH is since 1977 in the distribution and manufacture of measuring devices and control……...

Notch Interfaces Inc.

Notch Interfaces Inc.

The mission of Notch Interfaces Inc. is to improve the human capacity to visualize, understand, a……...

KLA Instruments™

KLA Instruments™

KLA Instruments encompasses a broad portfolio of surface metrology and defect inspection solution……...

今日仪器
  1. AW-Lake Company

    AW-Lake Company

    AW-Lake Company, a TASI Group company, is a leading North American design, manufacturing and service company of flow measurement technology for the fluid control needs of various industries, includ……

    进口品牌 2025-10-03

  2. Mark-10 Corporation

    Mark-10 Corporation

    Mark-10 Corporation is a manufacturer of force and torque measuring instruments. Since our founding in 1979, our products have proven themselves in numerous applications at companies in the automot……

    进口品牌 2025-10-03

  3. Flamefast UK Ltd

    Flamefast UK Ltd

    Flamefast started manufacturing Bunsen Burners for British Gas in 1973 when the UK changed from using town gas to natural gas and from there very quickly became the main innovators for training eq……

    进口品牌 2025-10-03

返回顶部小火箭