Lion Precision offers the ECL150 and ECL150e Multi-Channel Eddy-Current Displacement Sensors. Up to eight channels of high-performance displacement sensing are integrated in a compact package.
Key Features
The main features of the ECL150 & ECL150e Multi-Channel Eddy-Current Displacement Sensors are:
Linearity: ±0.2%
Resolution (Typical, Dependent on Probe and Range)
ECL150 Non-ferrous: 0.006% RMS
ECL150 Ferrous: 0.008% RMS
ECL150e: 0.3 µm RMS or higher
Selectable Bandwidth (kHz): 0.25, 1, 10, 15
Low power/heat
Small volume package
±5 V DC outputs
1-8 Channels
Range indicating LEDs
CE Compliant
Available without enclosure
Probes can be ordered as vacuum compatible.
Specifications
The specifications of the ECL150 & ECL150e Multi-Channel Eddy-Current Displacement Sensors are as follows:
Resolution:RMS, Typical
Dependent on probe and range.See Range Table for resolution specifics. |
ECL150 | 0.006% RMS (Non-ferrous);0.008% RMS (Ferrous) |
ECL150e | Greater of 0.3 µm or0.006% RMS (Non-ferrous);0.008% RMS (Ferrous) | |
Linearity | ±0.2% of Range | |
Error Band | ±0.4% of Range | |
Maximum Bandwidth | 15 kHz | |
Driver Temperature Drift(15°C-50°C)
Typical. See Probe/Range chart for details. |
non-ferrous | ±0.01% F.S./°C |
ferrous | ±0.01% F.S./°C | |
Probe Temperature Drift(15°C-65°C)
Typical. See Probe/Range chart for details. |
non-ferrous | ±0.01% F.S./°C |
ferrous | ±0.01% F.S./°C | |
Analog Output | ±5 VDC, 0 Ù, 15 mA | |
Input Power | 12 to 24 VDC,1-2 Channels – 2.5 W3-4 Channels – 3.5 W5-6 Channels – 4.5 W7-8 Channels – 5.5 W | |
Driver Operating Environment | 4°C-50°CIP64 | |
Probe Operating Temperatures Standard Probes come with PUR (Polyurethane) jacketed cables. High Temperature Probes have FEP jackets. Other temperature ranges may be possible. Contact us for more information. Standard Probes: IP67 High Temperature Probes: IP63 |
U3 Probe |
Standard Probe (PUR Cable):-25°C to +125°C(Available with optional FEP cable) High Temperature Version Not Available |
U5-18 Probes |
Standard Probes:-25°C to +125°C High Temperature Probes:-25°C to +200°C |
|
U25-50 Probes |
Standard Probes:-25°C to +125°C High Temperature Probes:-25°C to +175°C |
Lapar Valve is the manufacturer of valves with about 40 years experiences, we set two factories i……...
Beckhoff implements open automation systems based on PC Control technology. The product range cov……...
In 1896, the founder of the Satake Corporation, Riichi Satake, invented and began the production ……...
A world leader in water treatment solutions, IDE specializes in the development, engineering, con……...
In the span of a century, IBM has evolved from a small business that made scales, time clocks and……...
An extremely accurate and quick high throughput analysis is provided by Micromeritics® TriSta……...
AW-Lake Company, a TASI Group company, is a leading North American design, manufacturing and service company of flow measurement technology for the fluid control needs of various industries, includ……
Mark-10 Corporation is a manufacturer of force and torque measuring instruments. Since our founding in 1979, our products have proven themselves in numerous applications at companies in the automot……
Flamefast started manufacturing Bunsen Burners for British Gas in 1973 when the UK changed from using town gas to natural gas and from there very quickly became the main innovators for training eq……