S60M TO-18 Single-Channel Silicon-Based Thermopile

上海仪舶实验室自动化 25-02-05 10:34:04

S60M TO-18 Single-Channel Silicon-Based Thermopile

Dexter‘s S60M TO-18 is a single-channel silicon-based thermopile that delivers high output. It features a small active area with dimensions of 0.6mm x 0.6mm in a small TO-18 package.

The silicon-based thermopile provides a rapid 18ms time constant in Argon encapsulation gas and faster 9ms time constant in Neon gas. In addition, the thermopile offers a low temperature responsivity coefficient of -0.04%/°C.

Benefits

The key benefits of the S60M TO-18 thermopile include:

Small active area

Fast time constant

High output

Low temperature responsivity coefficient

Applications

The S60M TO-18 thermopile can be used in the following applications:

Gas analysis

Non-contact measurement

Technical Specifications

The technical specifications of the S60M TO-18 are summarized in the following table:

Parameter Min Typical Max Symbol Units Comments
Active Area size .6 x .6 AA mm Hot junction size, per element.
Element Area .36 A mm2
Number of Junctions 72 Per element.
Number of Channels 1 Per detector package.
Output Voltage 89 Vs μV DC, H=330μW/cm2 (3)
Signal-to-Noise Ratio 2,320 SNR √Hz DC, SNR=Vs/Vn
Responsivity 74.9 V/W DC, ℜ=Vs/HA (2)
Resistance 65 90 120 R Detector element
Temperature Coefficient of ℜ -.04 %/°C Best linear fit, 0° to 85°C (1)
Temperature Coefficient of R .11 %/°C Best fit, 0° to 85°C (1)
Noise Voltage 32.6 38.4 42.4 Vn nV/√Hz Vn 2=4kTR
Noise Equivalent Power .51 NEP nW/√Hz DC, NEP= Vn HA/Vs (2)
Detectivity 1.17 D* 108cm√Hz/W DC, D*=Vs/ Vn H√A (2)
Time Constant 18 ms Chopped, -3dB point (1)
Field of View 76°/111° FOV Degrees See Assembly Drawings for FOV Description.
Package Type TO-18 Standard package hole size: Φ.080”
Operating Temperature -50 100 Ta °C

General Specifications: Flat spectral response from 100nm to > 100μm. Linear signal output from 10-6 to 0.1W/cm2. Maximum incident radiance 0.1W/cm2, damage threshold ≥ .5W/cm2

Notes: (1) Parameter is not 100% tested. 90% of all units meet these specifications. (2) A is detector area in cm2. (3) Test Conditions: 500K Blackbody source; Detector active surface 10cm from 0.6513cm Diameter Blackbody Aperture.

*Protected by U.S. Patent No. 5,059,543 and U.S. Patent No. 5,100,479

General Specifications

The general specifications of the S60M TO-18 are listed below:

Flat spectral response from 100nm to > 100µm

Linear signal output from 10-6 to 0.1W/cm2

Maximum incident radiance is 0.1W/cm2

Damage threshold is ≥ 0.5W/cm2

Notes

Specifications apply at 23°C with KBr window and nitrogen encapsulating gas

Parameter is not 100% tested. 90% of all units meet these specifications.

A is detector area in cm2.

Test conditions: 500K Blackbody source; detector active surface 10cm from 0.6513cm diameter blackbody aperture.

[S60M TO-18 Single-Channel Silicon-Based Thermopile]相关推荐
Radar, Inc.

Radar, Inc.

Radar, Inc. is a distributor of electronic components. In 1950, company founder, Mac McPherson st……...

INTEGRA Biosciences Ltd

INTEGRA Biosciences Ltd

Since 1965, INTEGRA Biosciences has been dedicated to the development of laboratory tools which a……...

Tek-Trol LLC

Tek-Trol LLC

Tek-trol is a global company that provides unique and cutting edge technology solutions for all p……...

Emerson Electric Co.

Emerson Electric Co.

Emerson concentrates on the most complex and profound challenges facing the world in the process,……...

今日仪器
  1. AW-Lake Company

    AW-Lake Company

    AW-Lake Company, a TASI Group company, is a leading North American design, manufacturing and service company of flow measurement technology for the fluid control needs of various industries, includ……

    进口品牌 2025-10-03

  2. Mark-10 Corporation

    Mark-10 Corporation

    Mark-10 Corporation is a manufacturer of force and torque measuring instruments. Since our founding in 1979, our products have proven themselves in numerous applications at companies in the automot……

    进口品牌 2025-10-03

  3. Flamefast UK Ltd

    Flamefast UK Ltd

    Flamefast started manufacturing Bunsen Burners for British Gas in 1973 when the UK changed from using town gas to natural gas and from there very quickly became the main innovators for training eq……

    进口品牌 2025-10-03

返回顶部小火箭