TowerJazz USA
TowerJazz manufactures advanced analog integrated circuits for a diversified and strong customer ……...
TecMicro O2-Oxygen Sensorsarechemical gas sensors capable of measuring oxygen levels ranging from a few parts per billion to 100% O2 by volume in ambient air or liquid, depending on the specific model.
These gas detection solutions are highly sought after in breweries, modified atmosphere packaging, head-space gas testing, bio-incubators, respirometers, and algae or aquatic applications.
Features
ATEX II approved for use in explosive atmospheres
Fast and accurate
Measure oxygen level in gas or liquid models
Measure from 0 ppb to 100% oxygen (depending on the model)
Optical sensor not sensitive to hydrogen or CO2
As it is all stainless steel, the TecMicro O2 oxygen Sensors can be used in clean-in-place (CIP) and sterilize-in-place (SIP) applications like incubation, brewing, or in the pharmaceutical or food processing industries. The sensor can withstand high temperatures, high pressure, cleaning agents, and anti-bacterial compounds.
Models
The following variants have a 5 VDC converter and an RS485 to USB connector, enabling direct communication between the sensor and the free GasLab software. A1/2" fine thread connector is readily available in stock, while other connectors can be provided upon request.
Gas Models
TS-402: Low: 0-5%
TS-403: Medium: 0–22%
Trace: 0-2,000 ppm for TS-401
High Range: 0–100% for TS-404
Liquid Models
TS-408: High Range: 0–40 mg/L
TS-407: Medium: 0–10 mg/L
TS-406: Low: 0-2,000 ppb (2 mg/L)
Trace: 0-200 ppb, TS-405
All versions are compatible with the TS-101 Stainless Steel 1/2" Calibration Gas Tee
Specifications - All
Average LED Lifetime:10,000+ hours
Cleaning:No organic solvents, 40% EtOH
Connection:½“ stainless steel hex nut
Data Interface:RS485 non-Modbus
Data Output:digital USB or RS485 non-Modbus
Dimensions:12 mm x 60 mm (½“-connector)
Materials touching sample:St.1.4404/PTFE/Glass
Manufacturer's recommended service interval:3 years
Power supply:5 VDC
Protection:IP65
Pressure compensation:STP by default. Change in software
Sensor cap replacement interval:12 months or more
Recommended zero-point calibration interval:3 months
Temperature compensation:-4 °C-40 °C (39 °F-104 °F)
Temperature range:-10 °C-60 °C (14 °F-140 °F)
Specifications - Models
TS-401 Trace Gas: 0-2,000 ppm
Accuracy1000-2000ppm:±4% MV
Accuracy100-1000ppm:±3% MV
Accuracy 0-100 ppm:± 2% MEV
Response Time at25°C:<15 seconds
Resolution:1 ppm
MaximumPressure:5 bar
Expected cap lifetime:1 year
TS-402 Low Range: 0-50,000 ppm (5%)
Accuracy 2.5-5%:± 2% MV
Accuracy 0.5-2.5%:± 2% MV
Accuracy 0-0.5%:± 2% MEV
Response Time at25 °C:5 seconds w/o protective layer
Resolution:0.001%
MaximumPressure:5 bar
Expected cap lifetime:2 years
TS-403 Standard: 0-220,000 ppm (22%)
Accuracy 15-22%:± 3% Mev
Accuracy 5-15%:± 3% Mev
Accuracy 0-5%:± 2% Mev
Resolution:0.001%
Response Time at25 °C: 5 seconds w/o protective layer
MaximumPressure: 5 bar
Expected cap lifetime: 2 years
TS-404 High Range: 0-100%
Accuracy 22-100%: ± 5% MV
Accuracy 5-22%: ± 4% MV
Accuracy 0-5%: ± 3% MEV
Resolution: 0.001%
Response Time at25 °C: 0.5 seconds w/o protective layer
MaximumPressure: 5 bar
Expected cap lifetime: 2 years
TS-405 Trace Liquid: 0-200 ppb
Accuracy:0-200ppb:± 2% MEV
Resolution: 1 ppb
Response Time at25 °C: <20 seconds
MaximumPressure: 20 bar
Expected cap lifetime: 1 year
TS-406 Low Range: 0-2,000 ppb (0-2 mg/L)
Accuracy: 1000-2000 ppb:± 2% MV
Accuracy: 200-1000 ppb:± 2% MV
Accuracy:0-200 ppb:± 2% MEV
Resolution: 1 ppb
Response Time at25 °C: <20 seconds
MaximumPressure: 20 bar
Expected cap lifetime: 1 year
TS-407 Medium Range: 0-10 mg/L
Accuracy: 8-10mg/L:± 3% MV
Accuracy: 2-8 mg/L:± 3% MV
Accuracy:0-2 mg/L:± 2% MEV
Resolution: 0.001 mb/L
Response Time at25 °C: <20 seconds
MaximumPressure: 20 bar
Expected cap lifetime: 2 years
TS-408 High Range: 0-40 mg/L
Accuracy:0-2 mg/L:± 3% MEV
Accuracy: 2-8 mg/L:± 4% MV
Accuracy: 8-10mg/L:± 4% MV
Accuracy: 10-40mg/L:± 5% MV
Resolution: 0.001 mg/L
Response Time at25 °C: <20 seconds
MaximumPressure: 20 bar
Expected cap lifetime: 2 years
- MEV = Measured end value- MV = Measured value
Dissolved Liquid Cross Sensitivity
While the TecMicro has low cross-sensitivity (is monoscopic) to other gases, dissolved oxygen sensors can be sensitive to the following:
Gaseous sulfur dioxide (SO2) or chlorine (CL2)
Alcohols greater than 5%
Hydrogen peroxide (H2O2) greater than 3%
Sodium hypochlorite (NaClO, commercial bleach) greater than 3%
If the measurements exhibit instability despite following other troubleshooting procedures, it is possible that interfering substances are present in the solution.
None of the following interfere:
Carbon Dioxide (CO2)
Hydrogen sulfide (HS-)
pH, or any ionic species like sulfide (S2-), sulfate (SO4-2), chloride (Cl-)
Ammonia (NH3) pH
Software
The TecMicro features a free software utility that enables users to graph oxygen levels over time, save data, calibrate the sensor, and update the calibration when installing a new sensor cap.
System Requirements
Version XP SP2 or newer
Microsoft Runtime Libraries for .Net 3.5
TowerJazz manufactures advanced analog integrated circuits for a diversified and strong customer ……...
The Voith Group is a global technology company. With its broad portfolio of systems, products, se……...
Broadwin Technology, Inc. develops web-enabled automation software for industrial, energy, manufa……...
For applications that demand superior performance, look to the Sapphire EV76C541. This cutting-ed……...
The University of Surrey is one of the UK’s top professional, scientific and technological ……...
MTI Instruments offers a wide range of standard capacitance probes that can operate with any of t……...
AW-Lake Company, a TASI Group company, is a leading North American design, manufacturing and service company of flow measurement technology for the fluid control needs of various industries, includ……
Mark-10 Corporation is a manufacturer of force and torque measuring instruments. Since our founding in 1979, our products have proven themselves in numerous applications at companies in the automot……
Flamefast started manufacturing Bunsen Burners for British Gas in 1973 when the UK changed from using town gas to natural gas and from there very quickly became the main innovators for training eq……