Thermo Scientific™ 5014iQ Beta Attenuation Monitor

上海仪舶实验室自动化 26-01-30 13:51:14

Thermo Scientific™ 5014iQ Beta Attenuation Monitor

The Thermo Scientific™ 5014iQ Beta Attenuation Monitor is designed to track levels of TSP, PM-2.5, PM-10, and PM-1 in the surrounding air. Its automatically advancing filter tape captures PM samples in a clean area, minimizing the need for attended operation.

To help reduce particle loss, user-defined parameters such as mass accumulation limits, flow rates, and continuous pattern advances are used to control the filter tape advancement.

The device monitors the sample conditions, removes moisture effects, adjusts the control system to heat only when necessary, and ensures that volatile aerosols are preserved for accurate measurement.

Product Overview

Specifications. Source:Thermo Fisher Scientific – Environmental and Process Monitoring Instruments

. .
Flow Rate 1 m3/h (16.67 L/min) measured across an internal subsonic orifice, user selectable 14 to 20 lpm
Gases Measured Carbon-14 (C-14), < 3.7 MBq (<100 μCi)
Temperature (English) Operating The temperature of sampled air may vary -30 to 50 °C. 5014iQ Monitor must be weather protected within range 4 to 40 °C, an optional complete outdoor enclosure provides complete weather protection
Accuracy ±5% using SI-traceable mass foil set (for mass measurement)
Certifications/Compliance U.S. EPA PM-2.5 equivalent monitor (EQPM-1609-183)
CommunicationProtocols MODBUS, TCP/IP, Gesytec (Bayern-Hessen), streaming data and NTP (Network Time Protocol) protocols. Simultaneous connections from different locations over Ethernet
Concentration Measurement Range 60 to 3,600 seconds and 24-hour
Data Averaging Every 1 second
Depth (English) 21.16 in.
Depth (Metric) 53.8 cm
Description 5014iQ Beta Attenuation Monitor
ElectricalRequirements Designed to meet CE: EN61326: 1997 + A1: 1998 + A2: 2001 + A3: 2003, EN61010-1 UL: 61010-1: 2004; CSA: C22.2 No. 61010-1: 2004; FCC: Part 15 Subpart B, Class B, UKCA
Height (English) 12.2 in.
Height (Metric) 31 cm
Measurement Range 0 to 10,000 μg/m3
Outputs
  • Standard ports 3 full-speed USB ports (one in front, two in rear) 1 gigabit ethernet port

  • Analog I/O (optional) 4 isolated voltage inputs 0–10 V 6 isolated analog voltages outputs, with 4 selectable ranges 6 isolated analog current outputs, with 2 selectable ranges

  • Digital I/O (optional) 16 digital inputs (TTL) 8 solenoid driver outputs,10 digital reed relay contact outputs

  • Serial ports (optional) 1 RS-232/485 port, 1 RS-485 external accessory port

  • Precision ±2.0 μg/m3, <80 μg/m3, 4–5 μg/m3 > 80 μg/m3 (24-hour average)
    Resolution 0.1 μg/m3
    Sampling Flowand Control
  • Sample flow precision: ±2% of measured value

  • Sample flow accuracy: <5% of measured value

  • Wattage
  • 100–240 VAC, 50–60 Hz recommended, 805 watts (115 V)

  • 880 watts maximum (220–240 V (instrument, heater & pump)

  • Weight (English) < 55.1 lbs.
    Weight (Metric) < 25 kg
    Width (English) 16.73 in.
    Width (Metric) 42.5 cm
    Unit Size Each

    Ongoing evaluation

    (EQPM-0609-183) equivalent monitor

    US EPA approved PM-10 (EQPM-1102-150) and PM-2.5

    High resolution, accuracy, and low detection limit

    ePort communication software and an improved user interface

    Improved connectivity over Ethernet

    Prolonged absence of supervision

    Remote access to data

    5014iQ Beta Attenuation Monitor.

    5014iQ Beta Attenuation Monitor.Image Credit: Thermo Fisher Scientific – Environmental and Process Monitoring Instruments

    5014iQ Beta Attenuation Monitor.

    5014iQ Beta Attenuation Monitor. Image Credit: Thermo Fisher Scientific – Environmental and Process Monitoring Instruments

    [Thermo Scientific™ 5014iQ Beta Attenuation Monitor]相关推荐
    Tesvolt

    Tesvolt

    Daniel Hannemann and Simon Schandert founded TESVOLT in the summer of 2014. Their goal is to deve……...

    ARTRON AMERICA

    ARTRON AMERICA

    ARTRON AMERICA, INC. is an expert trading house supplying many customers with diverse products in……...

    Novelis

    Novelis

    Novelis is the leading producer of flat-rolled aluminum products and the world’s largest re……...

    Oven Industries, Inc.

    Oven Industries, Inc.

    Oven Industries has specialized in the design and manufacture of custom electronic control system……...

    今日仪器
    1. Nu-Lite

      Nu-Lite

      Nu-Lite has helped build New Orleans by participating in many major construction ventures. A couple of the first were the building of theLouisiana Superdome (1975)and the development of the Poydras……

      进口品牌 2026-03-12

    2. Feature-Rich Forge 5GigE Camera Platform

      Feature-Rich Forge 5GigE Camera Platform

      The Forge is built on a brand-new camera platform that supports a feature and sensor set, allowing users to build robust and powerful systems quickly. It provides variable link speeds and the abili……

      进口仪器 2026-03-11

    3. ILEC GMbH

      ILEC GMbH

      ILEC Instruments was founded by Jürgen Schindler and Rudolf Brözel in 1981. All ILEC products are manufactured in Germany. The sailplane instrument manufacturing business started with the……

      进口品牌 2026-03-11

    返回顶部小火箭